Friday, December 27, 2013

Burglar Alarm With Timed Shutoff Circuit Diagram

When SI (sensor) is closed, power is applied to U2, a dual timer. After a time determined by C2, CI is energized after a predetermined time determined by the value of C5, pin 9 of U2 becomes low, switching off the transistor in the optoisolater, cutting anode current of SCR1 and de-energizing Kl. The system is now reset. Notice that (i6x C2) is less than (R7xC$). The ON time is approximately given by:(R7xC5)-(R6xC2) = Ton 


Burglar Alarm With Timed Shutoff Circuit Diagram


[Continue reading]

Monday, December 23, 2013

Build a 5 Zone alarm Circuit Diagram

This is a complete alarm system with 5 independent zonessuitable for a small office or home environment. It uses just 3CM IC`s and features a timed entry / exit zone, 4 immediatezones and a panic button. There are indicators for each zone a“system armed” indicator. The schematic is as follows:

5 Zone alarm Circuit Diagram

5 Zone alarm Circuit Diagram

 


Circuit Notes:
Each zone uses a normally closed contact. These can be microswitches or standard alarm contacts (usually reed switches).Suitable switches can be bought from alarm shops and concealed indoor frames, or window ledges.Zone 1 is a timed zone which must be used as the entry andexit point of the building. Zones 2 – 5 are immediate zones,which will trigger the alarm with no delay. Some RF immunity isprovided for long wiring runs by the input capacitors, C1-C5. C7and R14 also form a transient suppresser. The key switch acts asthe Set/Unset and Reset switch. For good security thisshould be the metal type with a key.

Operation:
At switch on, C6 will charge via R11, this acts as the exitdelay and is set to around 30 seconds. This can be altered byvarying either C6 or R11. Once the timing period has elapsed,LED6 will light, meaning the system is armed. LED6 may be mountedexternally (at the bell box for example) and providesvisual indication that the system has set. Once set any contactthat opens will trigger the alarm, including Zone 1. To preventtriggering the alarm on entry to the building, the concealedre-entry switch must be operated. This will discharge C6 andstart the entry timer. The re-entry switch could be a concealedreed switch, located anywhere in a door frame, but invisibleto the eye. The panic switch, when pressed, will trigger thealarm when set. Relay contacts RLA1 provide the latch, RLA2operate the siren or buzzer.
[Continue reading]

Friday, August 16, 2013

Refrigerator Door Alarm

Do your kids leave the door to the refrigerator open? Or does your celery reach out to keep the door from closing properly when you turn your back? Heres a simple circuit that beeps whenever the door is open for an extended period of time (which will also put a little pressure on the fridge loiterers in the house). 
Simple Refrigerator Door Alarm Circuit Diagram

The photocell has a very high resistance in the dark which drops very low when the door opens and the light turns on. The 22 uF capacitor begins to charge and when the voltage reaches the zener voltage, the beeper sounds. Closing the door allows the capacitor to discharge through the 10 meg.  resistor, resetting the beeper. The circuit draws very little power when the door is shut and only draws significant current when the beeper is sounding. The transistor may be a single NPN darlington such as the MPS-A14 or two 2N4401s connected as shown. Other types will also work. The delay may be changed by changing the value of the capacitor. It may be a good idea to add a 10 uF capacitor across the battery.
[Continue reading]

Tuesday, July 30, 2013

Sound Generator for Alarm

This is sound generator circuit.You can use this circuit for your alarm circuits.Here I have used common IC 4011.This circuit gives about 10W through a 8 ohm speaker.This circuit can be control (on and off) with sw1.



Note
# Use 12V smooth power supply for this
# Build this on a PCB
#If you are unable to find IC 4011 you can use Ic MC14011 or TC14011
[Continue reading]

Thursday, April 11, 2013

Motorbike Alarm

This simple to build alarm can be fitted in bikes to protect them from being stolen. The tiny circuit can be hidden anywhere, without any complicated wiring. Virtually, it suits all bikes as long as they have a battery. It doesnt drain out the battery though as the standby current is zero. The hidden switch S1 can be a small push-to-on switch, or a reed switch with magnet, or any other similar simple arrangement. The circuit is designed around a couple of low-voltage MOSFETs configured as monostable timers. Motorbike key S2 is an ignition switch, while switch S3 is a tilt switch. Motorbike key S2 provides power supply to the gate of MOSFET T2, when turned on. 
 
When you turn ignition off using key S2, you have approximately 15 seconds to get off the bike; this function is performed by resistor R6 to discharge capacitor C3. Thereafter, if anyone attempts to get on the bike or move it, the alarm sounds for approximately15 seconds and also disconnects the ignition circuit. During parking, hidden switch S1 is normally open and does not allow triggering of mosfet T1. But when someone starts the motorbike through ignition switch S2, MOSFET T2 triggers through diode D1 and resistor R5. Relay RL1 (12V, 2C/O) energises to activate the alarm (built around IC1) as well as to disconnect the ignition coil from the circuit. Disconnection of the ignition coil prevents generation of spark from the spark plug. Usually, there is a wire running from the alternator to the ignition coil, which has to be routed through one of the N/C1 contacts of relay RL1 as shown in Fig.1 Fig.2 shows the pin configurations of SCR BT169, MOSFET BS170 and transistor BC548.
Circuit diagram :

Motorbike Alarm-Circuit-Diagram
 Motorbike Alarm Circuit Diagram
Motorbike Alarm-Pin Configurations :

Motorbike Alarm-Pin configurations
Pin configurations of BT169, BS170 and BC548
Also, on disconnection of the coil, sound generator IC UM3561 (IC1) gets power supply through N/O2 contact of relay RL1. This drives the darlington pair built around T3 and T4 to produce the siren sound through loudspeaker LS1.  To start the vehicle, both hidden switch S1 and ignition key S2 should be switched on. Otherwise, the alarm will start sounding. Switching on S1 triggers SCR1, which, in turn, triggers MOSFET T1. MOSFET T1 is configured to disable MOSFET T2 from functioning. As a result, MOSFET T2 does not trigger and relay RL1 remains de-energised, alarm deactivated and ignition coil connected to the circuit.  Connection to the ignition coil helps in generation of spark from the spark plug. Keeping hidden switch S1 accessible only to the owner prevents the bike from pillaging. Tilt switch S3 prevents attempt to move the vehicle without starting it. Glass-and metal-bodied versions of the switch offer bounce-free switching and quick break action even when tilted slowly. 
 
Unless otherwise stated, the angle by which the switch must be tilted to ensure the contact operation (operating angle), must be approximately 1.5 to 2 times the stated differential angle. The differential angle is the measure of the just closed position to the just open position. The tilt switch has characteristics like contacts make and break with vibration, return to the open state at rest, non-position sensitivity, inert gas and hermetic sealing for protection of contacts and tin-plated steel housing. If you find difficulty in getting the tilt switch, you may replace it with a reed switch (N/O) and a piece of magnet. The magnet and the reed switch should be mounted such that the contacts of the switch close when the bike stand is lifted up from rest.
 
 
 
http://streampowers.blogspot.com/2012/05/motorbike-alarm.html 
[Continue reading]

Monday, April 8, 2013

Motion Sensor Switch Circuit for Alarm

Here’s a design circuit for motion sensor switch circuit is a motion sensor controlled automatic water sprinkler but you can easily add an alarm/light function too. Before beginning the construction contact your nearest electronics component vendor and procure a readymade box-type Passive Infrared (PIR) Motion Sensor unit. Such units, packed in a compact enclosure with power input and relay output terminals are widely available. Here’s the figure of the circuit;


Now install the PIR module hanging from a 3 meter high mast (to cover 10 meter radius area) and connect its supply and relay terminals to our finished and enclosed circuit, observing right polarity. A 4-core screened cable can be used for this interconnection. Power the circuit from a regulated 12VDC adaptor/solar power box.

Whenever the PIR module detect movement of a live body its relay output toggles and the switching mosfet (T1) in the circuit is switched to on via resistor R1 and related parts. As result, the EM relay at the output of T1 is activated and the electric sprinkler gets its supply through the relay (RLY1) contacts. This contacts (or spare contacts) can also be used to activate a high-power warning alarm.
[Continue reading]

Friday, March 29, 2013

Four in One Burglar Alarm

In this circuit, the alarm will be switched on under the following four different conditions: 1. When light falls on LDR1 (at the entry to the premises). 2. When light falling on LDR2 is obstructed. 3. When door switches are opened or a wire is broken. 4. When a handle is touched. The light dependent resistor LDR1 should be placed in darkness near the door lock or handle etc. If an intruder flashes his torch, its light will fall on LDR1, reducing the voltage drop across it and so also the voltage applied to trigger 1 (pin 6) of IC1. Thus transistor T2 will get forward biased and relay RL1 energise and operate the alarm. 

Sensitivity of LDR1 can be adjusted by varying preset VR1. LDR2 may be placed on one side of a corridor such that the beam of light from a light source always falls on it. When an intruder passes through the corridor, his shadow falls on LDR2. As a result voltage drop across LDR2 increases and pin 8 of IC1 goes low while output pin 9 of IC1 goes high. Transistor T2 gets switched on and the relay operates to set the alarm.

Four-in-One Burglar Alarm Circuit Diagram
Four-in-One Burglar-Alarm-Circuit-Diagram


The sensitivity of LDR2 can be adjusted by varying potentiometer VR2. A long but very thin wire may be connected between the points A and B or C and D across a window or a door. This long wire may even be used to lock or tie something. If anyone cuts or breaks this wire, the alarm will be switched on as pin 8 or 6 will go low. In place of the wire between points A and B or C and D door switches can be connected. These switches should be fixed on the door in such a way that when the door is closed the switch gets closed and when the door is open the switch remains open. If the switches or wire, are not used between these points, the points should be shorted. With the help of a wire, connect the touch point (P) with the handle of a door or some other suitable object made of conducting material. When one touches this handle or the other connected object, pin 6 of IC1 goes ‘low’.

So the alarm and the relay gets switched on. Remember that the object connected to this touch point should be well insulated from ground. For good touch action, potentiometer VR3 should be properly adjusted. If potentiometer VR3 tapping is held more towards ground, the alarm will get switched on even without touching. In such a situation, the tapping should be raised. But the tapping point should not be raised too much as the touch action would then vanish. When you vary potentiometer VR1, re-adjust the sensitivity of the touch point with the help of potentiometer VR3 properly. If the alarm has a voltage rating of other than 6V (more than 6V), or if it draws a high current (more than 150 mA), connect it through the relay points as shown by the dotted lines. As a burglar alarm, battery backup is necessary for this circuit. Note: Electric sparking in the vicinity of this circuit may cause false triggering of the circuit. To avoid this adjust potentiometer VR3 properly.

Source : http://www.ecircuitslab.com/2012/01/four-in-one-burglar-alarm.html
[Continue reading]